Hannah B Walker Photographics

Provence-Alpes-Côte d'Azur, FR

@hannahbwalker
Quick actions

SKU 5YPC2-1

TXC65-63 Miniature Circuit Breaker

TXC65-63 Circuit Breaker are used for industrial, commercial and so on.

Circuit Breakers

Price on request

No public price on this one — ask the supplier for a quote.

Details

Scope of Application TXC65-63 Circuit Breaker is used for the circuit of AC 50Hz, rated voltage of 110V/230/400V, rated current of 63A to protect overload and short-circuit, as well as use for normal circumstances of the infrequent circuit conversion, also be used as the isolating switch for cut-off circuit to protect circuit and equipment. TXC65-63 Circuit Breaker are used for industrial, commercial, high-rise and civilian residential and other places. Meet the standards: GB10963.1, IEC60898-1. Technical parameter ■ Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ■ Rated working voltage: 110V, 230V ~ (1P, 1P + N), 400V ~ (2 ~ 4P, 3P + N) ■ Isolation □ Mechanical contact indication window, realistic cut-off instructions □ The window is green and the contact is in the open state. The window is red and the contact is in the closed state ■ Impulse withstand voltage: 4kV ■ Max withstand current: 6kA Circuit Breaker ■ Mechanical life: 20,000 times ■ Electrical life: 10000 times ■ Ambient temperature □ Use ambient temperature: -5℃~+40℃ ■ Wiring □ Tunnel type terminal block □ Terminal area: 1 ~ 63A, for the wire of 25mm ² and below ■ Accessories □ OF auxiliary contact, SD alarm contact, MX + OF shunt release, MV over-voltage release, MN undervoltage release, MV + MN over-voltage release ■ Tripping characteristics □ Type B curve Protect load of smaller short-circuit current (such as power supply, long cable, electric motorized vehicles, etc.) Tripping characteristics: instantaneous trip range (3-5) In □ Type C curve Protect conventional load and distribution cables (such as home lighting boxes, power distribution boxes, etc.) Tripping characteristics: instantaneous trip range (5-10) In □ Type D curve Protect impact load with the large starting current (such as motors, power counters, transformers, etc.) Tripping characteristics: instantaneous trip range (10-14) In ■ Installation method: □ Mounted on the TH35-7.5 steel rail.

Welcome to NetU.AI

New to NetU? The code creates your account. Already have one? It logs you in.

Continue with Google
or

By continuing, you agree to our Terms of Service and Privacy Policy.

Sebastian NetU's AI assistant

Hi! I'm Sebastian, NetU's AI assistant. Sign in and ask me anything about NetU — finding buyers and suppliers, growing your network, groups, events, and more.

Sign in to ask Sebastian

Prefer a person? Contact support.