Hannah B Walker Photographics

Provence-Alpes-Côte d'Azur, FR

@hannahbwalker
Quick actions

SKU 5YPC2-18

ZN63A-12 indoor high voltage vacuum circuit breaker

ZN63A-12 indoor high voltage vacuum circuit breaker

Circuit Breakers

Price on request

No public price on this one — ask the supplier for a quote.

Details

Product description ZN63A-12KV indoor high voltage vacuum circuit breaker is aindoor equipment with three phase AC 50Hz and rated voltage of 12kV, which can be used for the control and protection of electrical facilities in industrial and mining enterprises, power plants and substations, and is suitable for frequent operation places. The voltage vacuum circuit breaker can be operated frequently and has the ability to break and reclose multiple times. The product is designed as front-rear assembling structure, it not only can be used as fixed installation unit, but also can be used as handcart unit through equipping with chassis, and has a reliable interlocking function. ZN63A 12KV circuit breaker meet the standards: GB/T1984 and JB/T3855. Working condition 1. Ambient air temperature: -15~+40℃ 2. Altitude: ≤2000m 3. Humidity: Daily average value ≤95%,Monthly average value ≤90%; 4. Water vapor pressure: Daily average value ≤2.2kPa; Monthly average value ≤1.8kPa 5. The external shocking and earthquake could be neglected 6. No operating in such places as subject to dust, smog, corrosive / flammable gas, vapor and salt pollution. Technical Specification Rated voltage: 12kV Rated lightning impulse withstand voltage (peak): 75kV 1min power frequency withstand voltage: 42kV Rated short-circuit breaking current: 20, 25, 31.5, 40kA Rated current: 630, 1250, 1600, 2000, 2500, 3150, 4000A Rated thermo stability current (valid): 20, 25, 31.5, 40kA Rated dynamic stability current (peak): 63, 80, 100kA Rated short-circuit making current (peak): 50, 63, 80, 100kA Rated operations of short-circuit breaking current interruption: 50times Power frequency withstand voltage of secondary circuit (1min): 2000V Rated operation sequence: O-0.3s-CO-180s-CO;O-180s-CO-180s-CO(40kA) Rated thermo stability time: 4s Rated back to back capacitor bank breaking current Mechanical life: 20000times; 10000 times (40kA)

Welcome to NetU.AI

New to NetU? The code creates your account. Already have one? It logs you in.

Continue with Google
or

By continuing, you agree to our Terms of Service and Privacy Policy.

Sebastian NetU's AI assistant

Hi! I'm Sebastian, NetU's AI assistant. Sign in and ask me anything about NetU — finding buyers and suppliers, growing your network, groups, events, and more.

Sign in to ask Sebastian

Prefer a person? Contact support.