JIanzhi casting group
yutian county, SG
@jianzhi-casting-group
Quick actions
SKU OZVHO-22
Online Flue gas monitoring system OC-204-NOx
The VOCs online gas analyzer OC-204-VOCs is a new gas analyzer system, can monit
Other ScienceTesting & Measurement Equipment
Price on request
No public price on this one — ask the supplier for a quote.
Details
Description:
The on-line monitoring system for flue gas emission is mainly used in the gas analysis
industry. The main principle is to sample the flue gas or the gas measured at high
temperature and humidity for cooling, dehumidifying, dust filtering and tar filtering,
to keep the temperature and humidity of the measured gas in a certain range, so that
the gas analyzer can detect the concentration normally. The whole process is
automated without any need. Man-made intervention. The flue gas detection
pretreatment system is used in the occasions of less dust, high temperature and high
humidity. For the occasions of more dust and tar, more tar treatment system is needed.
It’s used to monitor the concentration of nitrogen oxides produced by boiler exhaust
gas and low nitrogen burner is specially designed. It can freely add oxygen, carbon
monoxide, sulfur dioxide and other parameters to monitor and analyze at the same
time according to the customer's on-site environment.
Features:
24hours real-time monitor of the Nitrogen oxide emissions from Boilers, Chimneys,
Low nitrogen burners and other related equipment.
With analysis function and built-in high precision NOx analysis module to analyze the
Nitrogen oxide components precisely.
Supporting multi data transmission mode: wireless transmission and wired
transmission.
With data storage function, the capacity is up to 2 years.
With the display function to show the detection data and analysis data real-time.
The system can freely add the Oxygen, Carbon Monoxide, Sulfur Dioxide and other
parameters for simultaneous monitoring and analysis.
Technical specification:
Working principle: Electrochemical sensor
Measuring range: NOx: 0~20/50/100/200/500/1000/2000/5000ppm or
customized
Sampling mode: Pump-suction sampling
Resolution: 0.1ppm
Precision: ≤±3%F.S
Repeatability: ≤±1%
Zero drift: ≤±1% F.S/6h
Span drift: ≤±1% F.S/6h
Response time: <30S(T90)
Power voltage: 24VDC
Working environment: Pressure: 80Kpa-120Kpa
Temperature: -20℃~+50℃;
Humidity: 10%RH ~95%RH(non-condensing)
Output signal: RS485, GPRS
System size: 800mm*500mm*400mm
Pump working life: More than 10000 hours continuously
If you are interested, pls contact us:
Email: [email protected];
Tel: +86-371-60998169