Jingman Medical Company

University Road, SG

@jingman-medical-company
Quick actions

SKU RFEFA-G3600

1kw-5kw UV lamp ballast

For UV lamp 1kw-5kw/120V-400V

Industrial Power Supplies

Price on request

No public price on this one — ask the supplier for a quote.

Details

Power Range 1.0KW-5.0KW Size and weight 37cm*15cm*13cm 5.2kg INPUT Rated voltage and frequency 3-phase (4T#Series) 380V 50/60 HZ 3-phase (2T#Series) 220V 50/60 HZ Single phase(2S#Series) 220V 50/60HZ Votage range 3-phase(4T#series)340V~460V 3-phase(2T#series)180V~260V single phase(2S#series)180V~260V Digital input 3 Route DI1/DI2/DI3 Analog input 1 Route AI (0~10V or 0~20mA) OUTPUT Voltage "4T#Series:200~500V 2T#Series:120~300V 2S#Series:120~300V" Current ≤16A Frequency 1KHz Digital output 3 Route:DO1/DO2/DO3 Analog output 2 Route:AO1/AO2(0~10V) Relay contact output 1 group: AC250V/2A normally open( TA/TC), Normally closed ( TA/TB) contact Control Function Efficiency >96% Power setting Resolution 0.1KW Power adjust range 20% ~100% step-less adjustable Current restrict 110% of UV lamp rated current Voltage restrict 110% of UV lamp rated voltage Power restrict Max output UV lamp rated power Typical function Standby function Set standby power consumption when equipment interval to save energy UV lamp running time record Real-time record UV lamp running time Operation function External dry contact signal and RS485 signal to control start/stop Communication function Control EPS start/stop, revise function parameter, read and write status parameter Communication interface RS485 Operation panel display Status monitor Real-time monitor output power, output current, output voltage, module temperature and setting power Alarm content Latest 6 failures and output power, output current, output voltage, DC voltage and module temperature of latest failure. Protection/Alarm function 3-phase input default phase, input over voltage, input under-voltage, output over current, output short circuit, machine over temperature, abnormal temperature detection, output break line, internal memory damage, etc. Environment temperature Working environment temperature: -10℃~+40℃, storage environment temperature:-20℃~+60℃ Protection class IP20 Cooling Forced air cooling Package Carton box

Welcome to NetU.AI

New to NetU? The code creates your account. Already have one? It logs you in.

Continue with Google
or

By continuing, you agree to our Terms of Service and Privacy Policy.

Sebastian NetU's AI assistant

Hi! I'm Sebastian, NetU's AI assistant. Sign in and ask me anything about NetU — finding buyers and suppliers, growing your network, groups, events, and more.

Sign in to ask Sebastian

Prefer a person? Contact support.