Nanjing East Inflable Manufacturing Co.- Ltd

C-15, NO.288 Xiongzhou South Road,Luhe District, CN

@nanjing-east-inflable-manufacturing-co-ltd
Quick actions

SKU 37XVE-100

UL 1581 Flame Test Chamber

UL Single Cable Flame Retardant Test

ScienceTesting & Measurement Equipment Machinery

Price on request

No public price on this one — ask the supplier for a quote.

Details

ST-7601D Single Cable H/V Flaming Tester (UL1581) Standards: According to the clause 1060 (vertical burning and FT1 test), 1061(cables burning test), 1080(VW-1 burning test), 1090(electric cable specimen horizontal burning test, optional item), 1100 (horizontal specimen/ FT2 burning test)of UL1581-2008, 6.8 (standard arcing test), clause 9.1~9.5 of UL2556-2007, clause 4.26 of JIS C3005-2000 Scope: Apply to check the single cable flaming test for FT1, FT2/FH/Horizontal flame, FV-2/VW-1, FV-1/Vertical flame, and standard arcing test; Main parameters: 1. Testing Chamber: L2200*D1300*H1650mm, capacity>4.0 m3;upper capacity of flame is more than 2.0m3, there is glass windows on the face, a pair of operational rubber gloves and smoke exhaust system on the top of the chamber; 2. Bunsen burner: Which according to ASTM D5025-2005 standard, Inside diameter of the burner tube is 9.5mm by length is 100mm, the Gas spout diameter is 0.9mm by thickness is 1.6mm. Which burn gas is methane at 98% minimum purity, the inner flame height is 40±2mm, the outer flame height is 125±10mm, nominal rate is 500W with a flame ruler which can check the flame height whether it meet requirement at any time. 3. Temperature measurement system: According to ASTM D5207-2003 standard, including 10g temperature measurement copper pieces, Type K stainless steel thermal which diameter is 0.5mm, stopwatch and thermometer. 4. Specimen stands: Horizontal and vertical stands both independent, which made by Stainless steel. The vertical stand could do the vertical burning test & FT1 test, cables flaming test, VW-1 flaming test and horizontal specimen/FT2 flaming test. The horizontal stand only for electric cable horizontal specimen flaming test.

Welcome to NetU.AI

New to NetU? The code creates your account. Already have one? It logs you in.

Continue with Google
or

By continuing, you agree to our Terms of Service and Privacy Policy.

Sebastian NetU's AI assistant

Hi! I'm Sebastian, NetU's AI assistant. Sign in and ask me anything about NetU — finding buyers and suppliers, growing your network, groups, events, and more.

Sign in to ask Sebastian

Prefer a person? Contact support.