VS1 12KV vacuum circuit breaker VCB

VS1 12KV vacuum circuit breaker VCB

Switches

Price on request

No public price on this one — ask the supplier for a quote.

Details

1.General VS1 12KV vacuum circuit breaker VCB HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker VCB (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism. 2. Service conditions 3.1 Environment temperature:-15degree~+40degree; 3.2 Environment humidity: Daily average relative humidity:<95%, monthly average relative humidity:<90%; Daily average saturated vapor pressure:<2.2×10-3Mpa,monthly average saturated vapor pressure:<1.8×10-3Mpa; 3.3 Altitude: Not exceed 1000m; 3.4 Earthquake intensity: Not exceed°ree; 3.5 Service location: No water, flammable or explosive matter, chemical corrosive gas or drastic vibration. 1.Main specifications and technical parameters Rated voltage: 12 kv Rated lightning impulse withstand voltage(1min): 75 kv Rated short-time power frequency withstand voltage (1min): 42 kv Rated short-circuit breaking current: 20KA / 25KA / 31.5KA / 40KA Rated current: 630A,1000A,1250A / 630A,1000A,1250A,1600A / 1250A,1600A,2000A,2500A / 1600A,2000A,2500A,3150A Rated peak withstand current: 50KA / 63KA / 80KA / 100KA Rated shorted-time withstand current: 20KA / 25KA / 31.5KA / 40KA Rated shorted-time making current(peak): 50KA / 63KA / 80KA / 100KA Power frequency withstand voltage of secondary circuit(1min): 2000 v Opening time(rated voltage): 20~50 ms Closing time(rated voltage): 30~70 ms Rated short-circuit current breaking times: 50(40kA 30) times Mechanical life: 30,000 times

Welcome to NetU.AI

New to NetU? The code creates your account. Already have one? It logs you in.

Continue with Google
or

By continuing, you agree to our Terms of Service and Privacy Policy.

Sebastian NetU's AI assistant

Hi! I'm Sebastian, NetU's AI assistant. Sign in and ask me anything about NetU — finding buyers and suppliers, growing your network, groups, events, and more.

Sign in to ask Sebastian

Prefer a person? Contact support.