SKU JPXMP-005

TADT portable humidity generator

It is a portable and high-precision temperature and humidity calibration instru

Science Testing Equipment

Price on request

No public price on this one — ask the supplier for a quote.

Details

TADT portable humidity generator is a portable and high-precision temperature and humidity calibration instrument, which can meet the needs of measurement and calibration of conventional temperature and humidity measuring instruments such as temperature and humidity sensors, temperature and humidity transmitters, small temperature and humidity meters, etc. The test chamber space is (2~4) times that of the same product, and the test chamber of the same product is (2~4) L, this model standard test chamber volume 8 L, can be customized for customers alone extended test chamber volume can reach 12 L; The test chamber can accommodate various types of input cold mirror dew point probe, which is convenient for comparison and calibration; Combined sensor jack design, can be adapted to various diameter temperature and humidity sensors and transmitters; Can be calibrated at the same time (10~15) only small temperature and humidity probe; The test chamber provides temperature uniformity within 0.1℃ in the range of 5℃~50; External drying cylinder design, desiccant replacement in the state of on-line operation, convenient and simple; Two-zone drying cylinder design, supporting both molecular sieve and discoloration silica gel desiccant; Visual liquid level and dryer state display, conducive to the working process of state monitoring; The instrument has built-in humidity conversion software, which is convenient for users to convert relative humidity, temperature and dew point temperature; Support temperature and humidity curve display, easy for users to view the temperature and humidity state trend; 7-inch color LCD touchscreen Temperature and humidity technical indicators Nominal range of humidity 5%rh~95%rh Nominal temperature range 5℃~50℃ Limit temperature range 2℃~60℃ Temperature stability ±0.03℃ Temperature uniformity ≤0.05℃(23±5℃) ≤0.1℃(5~50℃) Maximum allowable temperature error ±0.05℃(23±5℃) ±0.1℃(5~50℃) Humidity stability ±0.2%RH Humidity uniformity ≤1%RH(23±5℃) ≤1.5%RH(5~50℃) Maximum allowable error of relative humidity ±1%RH(23±5℃) ±1.5%RH(5~50℃) desiccant Molecular sieve or discolored silica gel (renewable) Saturated media Distilled or deionized water Test cavity size (length × width × height) Standar Type 240 mm×185 mm×185 mm (approximately 8 L) Extension Type 350 mm×180 mm×180 mm (approximately 12 L) Sensor Test Panel Modular design, support customized on demand Maximum opening diameter of test panel 60 mm Maximum number of openings in test panels 15 Communication interface RS232 General technical indicators Power requirements 220VAC±10% 50Hz Power 450W Temperature range Use (5~35)℃ Storage (0~70)℃ Humidity range Use (0~85)% rh Storage (0~100)% rh Weight 20kg Size (length × width × height) 550 mm ×300 mm ×600 mm

Welcome to NetU.AI

New to NetU? The code creates your account. Already have one? It logs you in.

Continue with Google
or

By continuing, you agree to our Terms of Service and Privacy Policy.

Sebastian NetU's AI assistant

Hi! I'm Sebastian, NetU's AI assistant. Sign in and ask me anything about NetU — finding buyers and suppliers, growing your network, groups, events, and more.

Sign in to ask Sebastian

Prefer a person? Contact support.