@shenzhen-alitonda-gifts-technology-coltd
Quick actions

SKU FQ5V1-3252

Intelligent multi turn flange connected electric actuator sipos or Equivalent

Other Electrical Equipment

Price on request

No public price on this one — ask the supplier for a quote.

Details

he specification of configurable valve Product type Output torque Action time Power Supply Soft sealed butterfly valve Metal sealed butterfly valve Ball valve SSSSSSAA Aeration butterfly value ≤PN1.6MPa ≤PN0.1MPa 0000000000 BYS-05 50N.M 15S/30S/60S AC24V.110V.220V 380V.DC12V DC24V.DC220V ≤DN62 ≤DN40 ≤DN32 ≤DN50-DN80 BYS-10 100N.M 15S/30S/60S DN80~DN125 DN40~DN65 DN40~DN50 DN100~DN200 BYS-20 200N.M 15S/30S/60S DN150~DN200 DN80~DN125 DN65~DN80 DN250~DN300 BYS-40 400N.M 15S/30S/60S DN200~DN250 DN125~DN150 DN80~DN100 DN300~DN400 BYS-50 500N.M 15S/30S/60S AC24V.110V.220V 380V.DC12V DC24V.DC220V DN250~DN300 DN150~DN200 DN100~DN125 DN400~DN500 BYS-60 600N.M 15S/30S/60S DN300 DN200~DN250 DN125 DN500~DN600 BYS-80 800N.M 45S DN350 DN250 DN150 DN800 BYS-100 1000N.M 45S DN300~DN350 DN250~DN300 DN150~DN200 DN800~DN900 BYS-200 2000N.M 45S DN400~DN450 DN300~DN350 DN200~DN250 DN900~DN1000 BYS-400 2000N.M 90S DN600 DN400 DN250 DN1200 BYS-600 0000000 2000N.M 135S DN700 DN500 DN300 DN1500 There are many different kinds of valves,so the working torqueof the valvewill bedifferentin conditions of different manufacturersand different operational environment,evenwithsame modelspecifications.Therefore, we suggested that whenyou arechoosingmodel ofactuatorthe outputtorqueof actuator shall beset in60%~80% asworkingtorqueof the valve. Explosion proof control circuit Limit position switch(standard BS model) Function:Through the switch circuit to achieve open, close operation, and output a set of active position signal (fully open, fully closed.) Passive contact type(S)circuit diagram Function:Through the switch circuit to achieve open, close the operation, and output a group of valves that are fully open, fully closed position passiveswitch signal. Structure:With two intermediate position switches Opening signal type(R)circuit diagram Function:Through the switch circuit control valve opening angle and output resistance and the corresponding position of the resistance signal. Structure:With 500Ωor1000Ω Potenti- ometer. DC24Vcontrol circuit(D Model) Function:Through the external circuit DC power positive and negative commutation, to achieve open, close operation andoutput a set of passive contact (fully open, fully closed) signal. Structure: With Intermediate position switch. Note:The electric device internal circuit is in the dotted lineof control circuit, outof the dotted line only for reference when userwiring. Attention!Don’t puttwo or several sets of electric power line in parallel, Don’tuse the same contact to control several electric devices, otherwise it will cause out of control and motor overheating. With control module (smart P type) Function:Adjustment, input 4-20mADV or 1-5VDC,output 4-20mADC. Structure:With control moduleand 1KΩ electric device. Three - phase AC switchH model(380V) Limit position switch(standard model)’s function fully open、fully close the limit position switch operation. Three - phase AC(380V)motor control electrical appliances(T Model) Feature:Through the external circuit control, to achieve the control circuit commutationand make the valve electric actuator toopen and close. While outputting a set of passive contact signals. AC220VWith position signal type (K Model) Function:Output 4-20mADC valve signal (to achieve full feedback the valve). Structure: With R/1 converterand 1KΩ potentiometer. Note:The electric device internal circuit is in the dotted lineof control circuit, outof the dotted line only for reference when userwiring. Attention!Don’t puttwo or several sets of electric power line in parallel, Don’tuse the same contact to control several electric devices, otherwise it will cause out of control and motor overheating. Common type control circuit Standard switch passive contact signal output circuit diagram(AS) ou Through the switch circuit to achieve thevalve open or close operation, and outputa set of activeposition signalto indicatevalve full openandclose and a set of passive position signal to indicatevalve full openandclose. Wiring instructions: Terminal 2 is connected to the power supply zeroline. When the power supply phase line is connected to the terminal 3, it is "ON"operation, and stop to the travelswitch OLSaction. At the same time,The "fully open signal" indicator connected to terminal 5 is on. When the power supply phase line is connected to the terminal 4, it is "OFF"operation, and stop to the travelswitch CLSaction. At the same time,The "fully open signal" indicator connected to terminal 5is on. Terminal 7 is the passive contact signal common. When “ON”running in place, terminal 8 outputs “fully open signal”. When “OFF”running in place, terminal 9 outputs “fully close signal”. Angel and active contacts signal output circuitdiagram (AR Model) Through the switch circuit to achieve thevalve open or close operation, and outputa set of activeposition signalto indicatevalve full openandclose, and output resistancesignal whichcorresponding to the opening position. Wiring instructions: Terminal 2 is connected to the power supply zeroline. When the power supply phase line is connected to the terminal 3, it is "ON" operation, and stop to the travelswitch OLSaction. At the same time,The "fully open signal" indicator connected to terminal 5 is on. When the power supply phase line is connected to the terminal 4, it is "OFF" operation, and stop to the travelswitch CLSaction. At the same time,The "fully open signal" indicator connected to terminal 6is on. Terminal 7 is potentiometer low end. Terminal 8 is potentiometer swing arm. Terminal 9 is potentiometer high end. DC Standard switch passive contact signal output circuit diagram (DS Model) Throughswitching the positive and negative poles of the external DC power supplyto achievethe"ON" and "OFF" operation of thevalve, andoutputa set of passive contact signals indicating fully openor fullyclose of the valve. Wiring instructions: When the terminal 3 is connected to thepositive pole of power supply, terminal 4 connected to the negative pole of power supplywasthe "ON" operation; when travelswitch CLSaction, the "fully open signal" indicator connected to terminal 5is on. When the terminal 3 is connected to thenegative pole of power supply, terminal 4 connected to the positivepole of power supplywasthe "OFF" operation; when travelswitch CLSaction, the "fully open signal" indicator connected to terminal6is on. Terminal 7 is the passive contact signal common. When “ON”running in place, terminal 8 outputs “fully open signal”. When “OFF”running in place, terminal 9 outputs “fully close signal”. SS With position signal output circuit diagram (K Model) Through the switch circuit to achieve thevalve open or close operation, and output current signal corresponding to theopening and closing angle of the valveat the same time. Output 4-20mADC valve position signal (provide feedbackof actualvalve stroke). Wiring instructions: The “N”which at power input terminal is zero line, the “L”connected to the phase line. When the “L”which at power input terminal is connected to “OFF”, run to the position of opening valve. When the “L”which at power input terminal is connected to “ON”, run to the position of closing valve. The “+”at “output signal”terminal connect positivepole of output signal, “-” connect negative pole of output signal. Note:The electric device internal circuit is in the dotted lineof control circuit, outof the dotted line only for reference when userwiring. Attention!Don’t puttwo or several sets of electric power line in parallel, Don’tuse the same contact to control several electric devices, otherwise it will cause out of control and motor overheating. I Intelligent adjustment model circuit diagram (P Model) Through the standard signal which input by outer computer or industrial instrument to control on-off angel of the valve, and synchronous provide feedback of output corresponding standard signal. Wiring instructions: The “N”which at “power supply”terminal connect to zero line, The “L”connect phase line The “+”which at “external control”terminal connect to positive pole of input signal, the “-”connect negative pole of input signal. The “+”which at “feedback”terminal connect to positive pole of output signal, the “-”connect negative pole of output signal. Analog quantity passive contact signal output circuit diagram (PS Model) Through the standard signal which input by outer computer or industrial instrument to control on-off angel of the valve, and synchronous provide feedback of output corresponding standard signal. And output a set of passive position signal to indicate valve fully open and close. Wiring instructions: Terminal 1 connect power supplyzero line; terminal 2 connect power supply phase line. Terminal 3 is the positive pole of input signal, terminal 4 is connected negative pole of input signal. Terminal 5 is the positive pole of output signal, terminal 6 is connected negative pole of output signal. Terminal 7 is the common terminal of the passive contact. When “ON”running in place, terminal 8 outputs “fully open signal”. When “OFF”running in place, terminal 9 outputs “fully close signal”. Switch value with feedback 4-20mA signal and passive d contact signal output circuit diagram (PS Model) Through the switch circuit to achieve thevalve open or close operation, and output current signal corresponding to theopening and closing angle of the valveat the same time. Output 4-20mADC valve position signal (provide feedbackof actualvalve stroke), and putout a set of passive position signal to indicate the valve to fully open and close. Wiring instructions: Terminal 1is connected to the power supply zeroline. When the power supply phase line is connected to the terminal 2, it is "ON" operation. When the power supply phase line is connected to the terminal 3, it is "OFF" operation. Terminal 5 is positive pole of output signal, terminal 6 is negative pole of output signal. Terminal 7 is the common terminal of the passive contact. When “ON”running in place, terminal 8 outputs “fully open signal”. When “OFF”running in place, terminal 9 outputs “fully close signal”. Termina 6 Three phase passive contact model circuit diagram (TS Model) Through the switch circuit to achieve thevalve open or close operation,and putout a set of passive position signal to indicate the valve to fully open and close. Wiring instructions: Terminal 1,2,3connect to three phase alternatingcurrent, Through the external invertercircuit to achieve positive and negative rotation of motor. Terminal 4 is common point of external control. Terminal 5 is running control of “ON”. Terminal 6 is running control of “OFF”. Terminal 7 is the common terminal of the passive contact. When “ON”running in place, terminal 8 outputs “fully open signal”. When “OFF”running in place, terminal 9 outputs “fully close signal”. Note:The electric device internal circuit is in the dotted lineof control circuit, outof the dotted line only for reference when userwiring. Attention!Don’t puttwo or several sets of electric power line in parallel, Don’tuse the same contact to control several electric devices, otherwise it will cause out of control and motor overheating. Product Introduction The series of BYS electric actuator is usedfor control rotation valve between 0% to 270% and other similar products, such as butterfly valve, ball valve, ventilation door, baffle valve, plug valve and louver valve etc. It can be used extensively for oil, chemical industry, water handles, ship, papermaking, power station, heating power, building automation and control, light industry and other industries. It uses ac power source of 380V/220V/110V as power supply ,4-20mA current signal or 0-10V DC voltage signal as control signal, to drive valve to required position, and achieve its automation control, Its biggestoutput torque is 60N·m. Performance Shell:dized hard aluminum alloywith polyester coating, having strong corrosion resistance, protection grade reaches IP67. Motor: Totally enclosed squirrel-cage machine, small volume, large torque, small inertia force, Insulation grade F, could prevent it fromoverheating damage. Manual structure: The design of handle ensuring it to be dependable, labor-saving and small volume. When it is not energized, pull handle to be in manual operation. Indicator: Indicator is installed on the central shaft, valve position can be observed through it. Lens use convex design, no waterlogging, more convenient to observe. Sealing: Good sealing, standard product protection grade is IP67. Limit Switch: mechanical, electronic double limit. Mechanical limit screw is adjustable, safe and reliable; electronic limit switch control by cam mechanism, simple adjusting mechanism can accurately and convenient set position , won’t affect by excess hand wheel. Self-hold: exact worm and gear organization can efficient transmit large torque, low noise and long life. Has self-hold function, prevents inversion, drive part is stable and reliable, no need further refueling. Anti-off bolt: The bolt will attach the shell when you dismantling the outer casing and won’t be fall off. Install: Mounting dimensions at bottom accord with ISO5211/DIN3337 international standard, the holes show double squareformto facilitateinstallation ofthe linearofthe square bolt or 45 ° corner installationand in strong adaptability. It can be installed vertically or level. Circuit: Control circuit accord with single phase or three phase power standard, circuit layout is compact and reasonable, the terminal can efficient satisfy various request of additional function. BYS-05 series sharp size and performance data Model Power BYS-05 DC12V DC24V DC220V AC24V AC110V AC380V AC220V 20W 15W 3.8A 2A 0.21A 2.2A 0.48A 0.15A 0.24A 30Nm/50Nm 15Nm/30Nm/50Nm 6S/10S 10S/20S/30S AS, AR, DS, K, P, PS, KS, TS Model, Intelligent non-invasive Model andRS485 bus type 0~360 degree adjustable 2.2Kg 100M/Ω/300DVC 100M/Ω/500DVC 500VAC/one minute 1500VAC/one minute IP67 -25 degree to +60 degree(other temperaturecan be customized) 360 degree installed at random angle Aluminum alloy precision die casting Heating dehumidifier

Welcome to NetU.AI

New to NetU? The code creates your account. Already have one? It logs you in.

Continue with Google
or

By continuing, you agree to our Terms of Service and Privacy Policy.

Sebastian NetU's AI assistant

Hi! I'm Sebastian, NetU's AI assistant. Sign in and ask me anything about NetU — finding buyers and suppliers, growing your network, groups, events, and more.

Sign in to ask Sebastian

Prefer a person? Contact support.