Faults and causes solution
Poor
heat
transfer performance Insufficient cooling water 1.Open large intake valve.
2.Check pipelines,valves,filters,whether heat exchanger tubes are blocked,if any,should be excluded.
Air exists in or between heat exchanger tubes. Turn down the screw plug to exhaust.
Fouling in or between heat exchanger tubes increases flow resistance. Cleaning of fouling on the inner and outer surfaces of heat exchanger tubes.
Water and oil mixing was found at the outlet. 1. When the leakage is caused by the breakage of the heat exchanger tube,it should be blocked by the pipe plug(the number of pipe plugs should not exceed 10% of the total number).
2. Replacement of leaky heat exchanger tubes.
3. The expansion joint of heat exchanger tube and tube sheet is loose and needs to be re-expanded.
Leakage occurred at flange bolt connection. 1. Tighten fasteners on flanges or replace gaskets.
2. After the cooler is disassembled,use new gaskets as far as possible.