@team-transformation
Quick actions

SKU LDD6X-15

Water Bath Apparatus of Boil Test for Safety Glazing Materials in Building

AS/NZS 2208 Safety glazing materials in buildings – Appendix F Boil Test

ScienceTesting & Measurement Equipment Machinery

Price on request

No public price on this one — ask the supplier for a quote.

Details

Related Standard: 1) EN ISO 12543 - 4 Glass in building -Laminated glass and laminated safety glass - Part 4: Test methods for durability – Clause 5 High-temperature test 2) AS/NZS 2208 Safety glazing materials in buildings – Appendix F Boil Test 3) GB 15763.3 Safety glazing materials in building Part 3:Laminated glass – Clause 7.8 Heat resistance test 4) ANSI Z97.1 Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test - Clause 5.3.2 – ( 1 ) Boil Test Data: 5) Power: 220V 50Hz 3Kw (Customized) 6) Outside Size: 430mm*290mm*575 mm 7) Inner Size: 400mm*255mm*480mm 8) Rack:340mm*235mm*350mm 9) At most 6 samples with 300mm*300mm Scope: 10) Determining the effect of exposure of safety glazing materials to temperature and humidity condition by boiling Principle: 11) Specimens are immerse in hot water and boiling water for specified period of time and inspect bubbles and others defects Apparatus: 12) The apparatus include two water baths, each of sufficient size to hold the test specimen fully immersed vertically on edge for the duration test. Samples: 13) Three specimen of size 300mm*300mm manufacture in a manner identical with impact test specimens and of like thickness shall be tested. 14) These specimens may be cut from production samples of the size and thickness submitted for impact testing. 15) For heat strengthened or toughened laminated glass, test specimen may be cut from a similar original sheet of annealed laminated glass Procedure: 16) Immerse the specimens vertically on edge in a bath of water maintained at a temperature of 66°C±3°C for 3 min 17) Quickly transfer the specimens to a bath of water maintain at boiling point. Immerse the specimens vertically on edge for 2 h 18) Remove the specimens and examine for the bubbles and others defects

Welcome to NetU.AI

New to NetU? The code creates your account. Already have one? It logs you in.

Continue with Google
or

By continuing, you agree to our Terms of Service and Privacy Policy.

Sebastian NetU's AI assistant

Hi! I'm Sebastian, NetU's AI assistant. Sign in and ask me anything about NetU — finding buyers and suppliers, growing your network, groups, events, and more.

Sign in to ask Sebastian

Prefer a person? Contact support.